LG Air Conditioner Error Codes

Hvac Error Codes

What’s in the article?

LG Air Conditioner Error Codes: The Complete List
Indoor Unit Faults
Outdoor Unit Faults
Other Error Codes

LG’s strong reputation for durability, innovative features,meeting both residential and commercial cooling needs effectively. But it doesn’t mean that your LG’s aircon might not run into problems sometimes. 

But worry not, because in this complete LG error code guide, we’ll show you the different codes and possible causes affecting LG aircon units — and how you can use them to check and troubleshoot the common issues with your LG air conditioner.

LG Air Conditioner Error Codes: The Complete List

Indoor Unit Faults

Error CodePossible CauseLED1 (Heating LED)LED2 (Cooling LED)
1Indoor unit room temperature sensor error1 blink0 blinks
2Indoor unit inlet pipe sensor error2 blinks0 blinks
4Drain pump / Float switch error (optional)4 blinks0 blinks
5Communication error between indoor unit and outdoor units5 blinks0 blinks
6Indoor unit outlet pipe sensor error6 blinks0 blinks
9Indoor unit EPROM error9 blinks0 blinks
10Indoor unit BLDC motor fan lock0 blinks1 blink
12Indoor unit middle pipe sensor error2 blinks1 blink
21DC Peak (IPM Fault); Compressor DC voltage was too high2 blinks1 blink
22Current Transformed (CT2) error; Alternating current (AC) input too high2 blinks2 blinks
23DC Link Low Voltage2 blinks3 blinks
25AC Low/High Voltage2 blinks5 blinks
26DC Comp Position Error (not providing rotation), Locking2 blinks6 blinks
27PSC Fault; Current to inverter compressor between AC and DC converter circuit too high2 blinks7 blinks
28Inverter compressor DC voltage is too high2 blinks8 blinks
29Inverter compressor amperage is too high2 blinks9 blinks
31Current-to-current transformer (CT) thermistor is too low3 blinks1 blink
32Inverter Compressor Discharge Pipe (D-Pipe) Overheat3 blinks2 blinks
40CT Sensor Error; Thermistor is disconnected or shorted out4 blinks0 blinks
41D-Pipe Sensor INV is disconnected or shorted out4 blinks1 blink
44Outdoor Air Sensor is disconnected or shorted out4 blinks4 blinks
45Middle thermistor of outdoor unit condenser coil is disconnected or shorted out4 blinks5 blinks
46Outdoor unit suction line thermistor is disconnected or shorted out4 blinks6 blinks
48Outdoor unit coil outlet (liquid line) thermistor is disconnected or shorted out4 blinks8 blinks
53Communication failure from outdoor unit to indoor unit5 blinks3 blinks
60Outdoor unit printed circuit board (PCB) EEPROM check sum error6 blinks0 blinks
61Outdoor unit condenser coil temperature is too high6 blinks1 blink
62Outdoor unit inverter compressor PCB heat sink temperature is too high6 blinks2 blinks
63Condenser coil pipe thermistor temperature is too low6 blinks3 blinks
65Heat sink thermistor has disconnected or has shorted out6 blinks5 blinks
67Outdoor brushless direct current (BLDC) fan motor lock error6 blinks7 blink

Outdoor Unit Faults

Error CodePossible CauseLED1 (Green)LED2 (Red)
21DC Peak (IPM Fault); Compressor DC voltage was too high2 blinks1 blink
22Current Transformed (CT2) error; Alternating current (AC) input too high2 blinks2 blinks
23DC Link Low Voltage2 blinks3 blinks
24Low / High Pressure2 blinks5 blinks
25AC Low/High Voltage2 blinks5 blinks
26DC Comp Position Error (not providing rotation), Locking2 blinks6 blinks
27PSC Fault; Current to inverter compressor between AC and DC converter circuit too high2 blinks7 blinks
28Inverter compressor DC voltage is too high2 blinks8 blinks
29Inverter compressor amperage is too high2 blinks9 blinks
31Current-to-current transformer (CT) thermistor is too low3 blinks1 blink
32Inverter Compressor Discharge Pipe (D-Pipe) Overheat3 blinks2 blinks
33Discharge pipe (cons.) overheat3 blinks3 blinks
34High-pressure sensor high3 blinks4 blinks
35Low-pressure sensor low3 blinks5 blinks
36Refrigerant leak detection3 blinks6 blinks
37Compression ratio limit exceeded3 blinks7 blinks
38Refrigerant leak detection3 blinks8 blinks
39Communication error3 blinks9 blinks
40CT Sensor Error; Thermistor is disconnected or shorted out4 blinks0 blinks
41D-Pipe Sensor INV is disconnected or shorted out4 blinks1 blink
44Outdoor Air Sensor is disconnected or shorted out4 blinks4 blinks
45Middle thermistor of outdoor unit condenser coil is disconnected or shorted out4 blinks5 blinks
46Outdoor unit suction line thermistor is disconnected or shorted out4 blinks6 blinks
48Outdoor unit coil outlet (liquid line) thermistor is disconnected or shorted out4 blinks8 blinks
53Communication failure from outdoor unit to indoor unit5 blinks3 blinks
60Outdoor unit printed circuit board (PCB) EEPROM check sum error6 blinks0 blinks
61Outdoor unit condenser coil temperature is too high6 blinks1 blink
62Outdoor unit inverter compressor PCB heat sink temperature is too high6 blinks2 blinks
63Condenser coil pipe thermistor temperature is too low6 blinks3 blinks
65Heat sink thermistor has disconnected or has shorted out6 blinks5 blinks
67Outdoor brushless direct current (BLDC) fan motor lock error6 blinks7 blink

Other Error Codes

Error CodePossible CauseSolution
Code appears in the display. F1,F2 or F3Air conditioner is in FAN mode and the number shown is the set fan speed.This is normal. The air conditioner is working properly.
FLThe water collection tank is full.Empty the water collection tank.
CH01Short or open circuit in the indoor air thermistor.Unplug the air conditioner and contact your authorized LG service center.

Still facing some issues with your LG air conditioner? Don’t forget to check your warranty before scheduling any repairs! If your LG air conditioner is still covered, you might be eligible for free repairs or parts replacement.  For any issues with your LC aircon, you should follow the steps here to request a repair.  

For more information about LG air conditioning error codes, feel free to consult the following links for additional reference: