Fujitsu Fault Codes Flashing Light
Sensor Light Codes
LED Codes
Fujitsu Error Codes List

Fujitsu Fault Codes Flashing Lights

Sensor Light Codes

Red Light SensorGreen Light Sensor原因
2 blinks2 blinksIndoor air sensor failure
2 blinks3 blinksIndoor unit pipe sensor failure
2 blinks4 blinkIndoor heat exchanger sensor error
2 blinks6 blinksFloat switch operated
3 blinks4 blinksOutdoor unit air sensor failure
3 blinks7 blinksHeatsink sensor error
4 blinks4 blinksPower failure
5 blinks5 blinksCompressor failure
5 blinks6 blinksOutdoor fan failure
7 blinks2 blinksHigh discharge temperature
7 blinks3 blinksHigh pressure
7 blinks4 blinks4-way discharge valve abnormal
7 blinks5 blinksPressure switch fail
7 blinks6 blinksCompressor temperature error
8 blinks4 blinksPFC circuit error
Consistent blinkingConsistent blinkingPCB failure

LED Codes

  • 1 flash: Indoor and outdoor unit communication error
  • 2 flash: Discharge pipe temperature sensor
  • 3 flash: Outdoor heat exchanger temperature (outlet) sensor
  • 4 flash: Outdoor temperature sensor error
  • 5 flash: Outdoor heat exchanger temperature (mid) sensor
  • 6 flash: Discharge pipe temperature abnormal
  • 7 flash: Compressor temperature sensor
  • 8 flash: Heat sink temperature sensor
  • 9 flash: Pressure switch abnormal
  • 10 flash: Compressor temperature abnormal
  • 12 flash: IPM error
  • 13 flash: Compressor rotor position cannot detect
  • 14 flash: Compressor error
  • 15 flash: Outdoor fan abnormal (upper fan)
  • 16 flash: Outdoor fan abnormal (lower fan)
  • 5 sec on/ 0.1 sec off repeat: PAM voltage abnormality
  • 5 sec on/ 1 sec off repeat: Protect operation
  • 5 sec on/ 2 sec off repeat: PFC surge protection (permanent stop)
  • 5 sec on/ 5 sec off repeat: Fan malfunction
  • 2 sec on/ 2 sec off repeat: CT abnormality
  • 2 sec on/ 5 sec off repeat: Compressor temperature protection (permanent stop)
  • 1 sec on/ 1 sec off repeat: Pump down operation
  • 0.5 sec on/ 0.5 sec off repeat: Current surge protection
  • 0.1 sec on/ 0.1 sec off repeat: Thermistor malfunction
  • 0.1 sec on/ 2 sec off repeat: Compressor position detection malfunction

Fujitsu Error Codes List

  • 00: Communication error between indoor unit and remote control
  • 01: Communication error between indoor unit and outdoor unit
  • 02: Room sensor open
  • 03: Room sensor short
  • 04: Indoor unit pipe sensor open
  • 05: Indoor unit pipe sensor short
  • 06: Outdoor pipe sensor open
  • 07: Outdoor pipe sensor short
  • 08: Power source connection failure
  • 09: Float switch
  • 0A: Outdoor unit sensor open
  • 0B: Outdoor unit air sensor short
  • 0C: Discharge sensor fail
  • 0D: Discharge sensor short
  • 0E: Outdoor high pressure heatsink error
  • 0F: High discharge temperature
  • 11: Communication error between indoor and outdoor units
  • 12: Remote control communication error
  • 18: External communication error
  • 1A: Compressor failure
  • 1B: Outdoor fan failure
  • 1C: Inverter to PCB communication error
  • 1D: Two-way valve sensor failure
  • 1E: Expanse valve error
  • 1F: Connection ID unit error
  • 22: Indoor unit capacity abnormal
  • 24: Excessive high pressure protection on cooling
  • 25: PFC circuit error
  • 26: Indoor unit address setting error
  • 27: Indoor signal error
  • 28: Indoor heat exchanger temperature error
  • 29: Connection unit number error in wired remote control system
  • 2A: Power supply frequency detection error
  • 2B: Compressor temperature error
  • 2C: Four-way valve abnormal
  • 2D: Heat sink thermistor failure
  • 2E: Inverter error
  • 2F: Low pressure error
  • 32: Indoor unit main PCB error
  • 35: Indoor unit manual auto switch error
  • 3A: Indoor unit communication circuit (wired remote) error
  • 41: Indoor unit room temperature thermistor error
  • 42: Indoor unit heat exchange temperature thermistor error
  • 51: Indoor unit fan motor error
  • 53: Indoor unit water drain abnormal
  • 57: Indoor unit damper error
  • 58: Indoor unit intake grille position error
  • 62: Outdoor unit main PCB error
  • 64: Outdoor unit active filter / PFC circuit error
  • 65: Outdoor unit IPM error
  • 71: Outdoor unit discharge temperature thermistor error
  • 72: Outdoor unit compressor temperature thermistor error
  • 73: Outdoor unit heat exchange temperature thermistor error
  • 74: Outdoor air temperature thermistor error
  • 76: Outdoor unit operating valve thermistor error
  • 77: Outdoor unit heat sink temperature thermistor error
  • 86: Outdoor unit pressure sensor error
  • 94: Outdoor unit trip detection
  • 95: Outdoor unit compressor motor control error
  • 97: Outdoor unit fan motor 1 error
  • 99: Outdoor unit 4-way valve error
  • A1: Outdoor unit discharge temperature 1 error
  • A3: Outdoor unit compressor temperature error