Friedrich Air Conditioner Error Codes

暖通空调错误代码

文章里有什么内容?

Friedrich air conditioner error code list
Friedrich portable air conditioner error code list
Friedrich window air conditioner error code list
Friedrich all-in-one air conditioner error code list
Friedrich heat pump air conditioner error code list
Friedrich multi-zone air conditioner error code list

If you’re having trouble with your Friedrich AC, start by checking the error codes to troubleshoot the issue. Troubleshooting error codes often requires the expertise of a licensed technician, but there are a few error codes you can easily fix at home. When you’ve encountered a problem with your Friedrich air conditioner, check out our troubleshooting guide and error code list to help you solve the issue at home!

List of Friedrich AC Error Codes

Friedrich Portable Error Codes

错误代码原因Possible CauseSolution
E1Electrical sensor is short on both temperature and PCB. Refrigeration system error code.There may be a broken or short circuit on the ambient temperature sensor.Check if this is a sensor problem. If not, contact the technician to replace the PCB.
E2Lack of power of temperature sensor copper tubes and PCB wires. Defective sensor error code.There may be a broken or short circuit on the brass temperature sensor (applicable only to the COOL / heat unit).Check if this is a sensor problem. If not, contact a technician to inspect the unit.
E4Poor connection to the water tank.The signal indicates incomplete or poor contact to the unit’s water tank.Take out the rubber stopper which is located at the bottom of the unit, allowing water to drain out. Check the plug is wired correctly.

Friedrich Window AC Error Code List

AC Error Code原因
CH01Discharge Air Temperature Sensor Error. Indoor air sensor open or small.
CH09EEPROM read date error.
CH34High pressure error. At high pressure, compile more than 10 bars in 1 hour.

Friedrich Packaged Terminal AC Error Code List

错误代码原因
E1High pressure system protection
E2Anti freezing protection
F0Refrigerant defects
E4High discharge temperature protection of compressor
E5Overcurrent Protection
E6Communication malfunction
E8High Temperature Resistant Protection
EEEEPROM Malfunction
EUFrequency reduction due to high temperature of module
C5跳线帽故障保护
DCBus bar PL voltage is too low
F1Indoor ambient temperature sensor is open / small circuit
F2Indoor evaporator temperature sensor is open / small circulated
F3Outdoor ambient temperature sensor is open / small circulated
F4Outdoor condenser temperature sensor is open / small circulated
F5Outdoor discharge temperature sensor is open / small circulated
F6Decrease frequency due to overload
F8Frequency decrease due to overcrack
F9Reduction in frequency of due to high air discharge
FHDecrease frequency due to anti freezing
H0Frequency of decreases due to high temperature resistor during heating operation
H1除霜
H2Static surrender protection
H3Overload protection for compressor
H4System is abnormal
H5IPM Security
H6Internal motor (fan motor) does not operate
H7Desynchronizing of Compressor
HCPFC Security
L3Outdoor DC Fan Motor Malfunction
L9Power Protection
LCFailure startup
LPDoes not match indoor unit and outdoor unit
P0Compressor minimum frequency in test state
P1Compressor rated frequency at test stage
P2Compressor maximum frequency in test state
P3Compressor intermediate frequency in test state
P5Overload protection of phase current for compressor
P7Module temperature sensor circuit malfunction
P8Module High Temperature Protection
PHVoltage too high for DC bus bar
U1Malfunction of phase current detection circuit for compressor
U3Malfunction of voltage dropping for DC bus bar
U5Malfunction current detection of complete units
U7Four-way valve is abnormal
U9Zero-crossing Outdoor Unit Malfunction

Numerical AC Error Code List

错误代码原因Solution
Error Code: 02Extremely low voltage conditions exist 198V for 230V units and 239V for 265V unitsShutdown unit
Error Code: 03Return air thermistor sensor open or short circuitSet the return air sensor = 75 ° F
Error Code: 04Indoor coil temperature sensor open or short circuitSet ID coil temp = 40 ° F
Error Code: 05Outdoor coil thermistor sensor open or short circuitSet indoor coil temp = 20 ° F.
Error Code: 06Outdoor coil temperature over 175 °FShut down unit for 5 minutes
Error Code: 07Indoor coil temperature is below 30 ° FShut down unit for 5 minutes. The compressor remains closed until the indoor coil thermistor reaches 45 ° F.
Error Code: 08Low load conditionsContact technician
Error Code: 09High load conditionsContact technician
Error Code: 10Room Freeze Protection TriggerKeep unit running

Friedrich Heat Pump Error Code List

错误代码原因
E1SHORT CYCLE SITUATION: Defined as a compressor that starts and stops more often (more than 6 times per hour).
E1SHORT CYCLE SITUATION: Defined as a compressor that starts and stops more often (more than 6 times per hour).
E2KEYBOARD ERROR: If a key button is stuck or pressed for 20 seconds or more, the unit gets stuck. If the key is stuck, it will be ignored until
E2KEYBOARD ERROR: If the key button is stuck or pressed for 20 seconds or more, the unit gets stuck. If the key is stuck, it will be ignored unt
E3AMBIENT (INDOOR) AIR PROBE OPEN or SHORT: Control will assume ambient temperature is 90 ° F when in cool mode and 60 ° F when in heat mode. The unit
E3FROST PROBE OPEN: Normal operation allowed. Change the probe.
E4EVAPORATOR TEMPERATURE PROBE OPEN or SHORT: Normal operation allowed. Change the probe.
E4FROST PROBE SHORT: Normal operation allowed. Change the probe.
E5CONDENSER TEMPERATURE PROBE OPEN OR SHORT: Normal operation allowed. Change the probe.
E5INDOOR PROBE OPEN: The control assumes that the indoor ambient temperature is 90 degrees F and the unit will operate. Change the probe.
E6INDOOR PROBE SHORT: The control assumes that the ambient temperature is 90 degrees F and the unit will operate. Change the probe.
E7Motor operation error
E9Heat pump failure

Friedrich Multi Zone Air Conditioner Error Code List

错误代码原因
00No error
01Indoor room themster error
02Indoor in-piping sensor error
03Remote controller error
04Drain pump error
05Communal error within and outside
06Indoor out-piping sensor error
07Different Mode Operation
09EEPROM even error check
10Indoor BLDC Fan Lock
21DC Peak (IPM Error) – Over rated current off
22CT2 (Max CT) – input of current off
23DC Link Low Voltage – DC link voltage is below 140Vdc off
24LP / HP Switch – Low / High Press Switch Open Close
25Low voltage / over-voltage – abnormal AC voltage input off
26DC Compressor Status Error – Compressor Start Fall Collapse Error
27PSC / PFC error – inverter PCB input current is over100A (peak) for 2us off
28DC Link High Voltage – Closed
29Overcurrent error – inverter compressor turned off
32D-Pipe High (INV) – Off Off
40CT sensor (short/open) – CT circuit malfunction
41INV. D-Pipe threshold – Open / Short Off
44Outdoor Air threshold – Open / Short Off
45Condenser Pipe threshold fault – Open / Short Off
46Suction Pipe Fault – Short/Open Off
51Overcapacity error – overloaded
52Signal error between DSP board and main board
53Signal error between indoor unit and outdoor unit.
61Condenser Pipe threshold High
62Heat Sink threshold High-Heat Temp. Drunk
65Heat Sink threshold – Open / Short Off
67Outdoor BLDC Fan Lock – Outdoor Fan Is Not Running Off
73PFC Fault Error (S / W) – Overall Outdoor Unit PFC

If you’re experiencing issues with your unit, you can reach their support team online: https://www.friedrich.com/consumer/contact-us