Trane Air Conditioner Error Codes

暖通空调错误代码

文章里有什么内容?

Common Fault Codes and Actions Taken
Trane Split-system Error Codes
Multi-Split Wired Controller
2-Trane Mini TVR 5G Error Codes

When you have a problem with your Trane air conditioner, you will be required to understand the underlying problem within your unit to troubleshoot it. More often than not, your Trane AC flashes an error code on its LED screen or remote control when the unit detects an internal problem. Decoding the meaning behind these error codes will help with the troubleshooting process.

In this article, we present the full list of error codes for your Trane air conditioner. Your air conditioning unit may have issues with a clogged filter, faulty pressure switch, or thermostat miscommunication. Always refer to your user’s manual for troubleshooting steps, or check out our guide on troubleshooting and restarting your Trane air conditioner.

Trane Error Codes

Common Fault Codes and Actions Taken

Fault Codes原因Action
0x01EEPROM communication error contact service technician. Unit stops working.Action to be taken by user: Contact service technician.
0x02Compressor failure or refrigerant leakage. Unit stops working.Action to be taken by user: Contact service technician.
0x03Filter choke error -Clean the air filter. Unit operates as per user settings.Action to be taken by user: Clean filters.
0x04Indoor Temp Sensor Error (Room). Thermostat Room Sensor Failure.Cool Mode Or Dry Mode: Unit Operate With Compressor Off Fan Mode: Operates As Per User Setting.
0x05Outdoor Temp Sensor Error. Outdoor Thermostat Sensor Failure.Operates Indoor Unit And Outdoor Unit As Per User Setting. If Trane Mode Is Activated Unit Should Operate At Set Point 24 °C.
0x06Indoor Coil Sensor Error. Indoor Thermostat Sensor Failure.Cool Mode Or Dry Mode: Unit Operates With Compressor Off Fan Mode: Operates As Per User Setting.
0x08Communication Error between the Indoor Unit and Outdoor UnitStop Indoor Unit And Outdoor Unit.
0x09Thermostat/Remote Control Low battery. Operates indoor unit and outdoor unit as per user setting.Change battery.
0x0AInput Power Error. Error 10 Idu Error – Input Power Problem. Unit Stops Working.Check The Power Cord / Contact Service Technician
0x0BFan Failure Error. IDU Error – Fan Failure. Unit Stops Working.Inspect and replace any faulty components.

Trane Split-system Error Codes

No LED light on outdoor PCB
Fault Codes原因
E1Indoor PCB malfunction
E2Anti-freezing protection
E5Overcurrent protection
EEStorage slug
F1Internal ambient temperature sensor malfunction
F2Indoor pipe temperature sensor malfunction
H3Overload of compressor
H4Overload system
H6No motor of indoor unit feedback
Lc启动失败
U1Phase current detection malfunction of compressor
U74-way valve conversion abnormal
UFZero passage abnormal
UHNo motor of outdoor unit feedback

LED light on outdoor PCB
Fault Codes原因
C5Jump wire cap malfunction protection
E1System high pressure protection
E2Anti-freezing protection
E4Compressor air exhaust high temp. protection
E5AC overload protection
E6Indoor and outdoor units communication malfunction
E8Anti-high temp. protection
EUIPM temp. is too high limit/decrease frequency
F1Indoor ambient sensor open circuit, short circuit
F2Indoor evaporator sensor circuit open, short circuit
F3Outdoor ambient sensor circuit open, circuit short
F4Outdoor condenser sensor open circuit, short circuit
F5Outdoor air exhaust sensor open circuit, short circuit
F6Overload limit/descending frequency
F8Overcurrent need frequency descending
F9Air exhaust over high need frequency descending
FHAnti-freezing limit/decrease frequency
H6Indoor unit motor no feedback
PHDC generatrix voltage
PLLow DC Bus voltage protection
U3DC Bus voltage dips
U7Four-way valve abnormal
U9Outdoor unit zero-cross detection error

Multi-Split Wired Controller

错误代码原因
B5Liquid Valve Temperature Sensor Open/Short circuited (Indoor Unit)
B7Gas Valve Temperature Sensor Open/Short circuited (Indoor Unit)
DNCommunication Line Disconnected/Expansion Valve Malfunction
E1High Pressure Prevention System
E2Anti-freezing Prevention System
E3Low Pressure Prevention System
E4Discharge High Temperature Prevention System
E5Overcurrent Prevention System; Frequency Decreased
E6Indoor and Outdoor Unit Communication Error
E7Running Mode Issue
E8Overload Prevention System; Frequency Decreased
E9Water Overflow Error (Indoor Unit)
ENIntelligent Power Module (IPM) Current Prevention System
EUIntelligent Power Module (IPM) Temperature Prevention System
F1Room Air Temperature Sensor Open/Short circuited
F2Evaporator Temperature Sensor Open/Short circuited
F3Ambient Temperature Sensor Open/Short circuited (Outdoor Unit)
F4Condenser Temperature Sensor Open/Short circuited (Outdoor Unit)
F5Discharge Temperature Sensor Open/Short circuited
F6Overload Protection; Frequency Restricted
F8Current Protection; Frequency Restricted
FOSystem Charge Shortage/Blockage Prevention/Pump Down
F9High Discharge Temperature; Frequency Restricted
FHAnti-freezing; Frequency Restricted
H1除霜
H3Compressor Overheating Preventive
H7Compressor Desynchronizing
H5Intelligent Power Module (IPM) Current Protection
H6Stalled Motor
HECompressor Demagnetization Protection
HCPower Factor Correction (PFC)
L3Outdoor Fan1 Error
L9Overpower Protection
LAOutdoor Fan2 Error
LCCompressor Startup Failure
LDCompressor Phase Loss/Reversal
LEStalling Compressor
LFSpeeding
LPIndoor and Outdoor Units Unmatched
P6Drive Board Communication Error Codes
P9Alternate Current (AC) Contactor Error Code
PDSensor Connection Error Code
PETemperature Drift Error Code
PFDrive Board Temperature Sensor Error Code
PUCapacitor Charging Error Code
P5Over Phase Current
P7Intelligent Power Module (IPM) Temperature Tensor Open/Short Circuited
P8Intelligent Power Module (IPM) Temperature Protection
PHDirect Current (DC) Bus Over-Voltage
PLDirect Current (DC) Bus Under-Voltage
PPAlternate Current (AC) Input Voltage Error Code
U1Compressor Phase Current Circuit Error Code
U3Sensor Connection Error Code
U5Current Circuit Error Code
U74-Way Valve Reversing Error Code
U8PG Motor Zero-Crossing Protection

2-Trane Mini TVR 5G Error Codes

Normal LED Displays:

  1. On Standby: LED screen displays the amount of indoor units communicating with outdoor units.
  2. On Operation: LED screen displays the frequency value of the compressor.
  3. On Defrost Setting: LED screen displays dF for defrosting.
Indoor Unit
Fault Codes原因
H0Malfunction or Protection: M_Home unmatching
E0Malfunction or Protection: EEPROM Fault
E2Malfunction or Protection: Communication fault of the outdoor chip and the indoor chip
E3Malfunction or Protection: Main board and IR341 not properly connected
E4Malfunction or Protection: Outdoor unit sensor fault
E5Malfunction or Protection: Voltage protection fault from circuit breaker
E6Malfunction or Protection: Direct-current fan fault
E7Malfunction or Protection: Heating fan fault in the area A lasts for 5 minutes
E8Malfunction or Protection: There are two times E6 fault in 10 minutes (recovery will be after power off)
P0Malfunction or Protection: The cooling fin high temperature protection
P1Malfunction or Protection: High pressure protection
P2Malfunction or Protection: Low pressure protection
P3Malfunction or Protection: Compressor current protection
P4Malfunction or Protection: Discharge temperature protection
P5Malfunction or Protection: Outdoor condenser high temperature protection
P6Malfunction or Protection: IPM modules protection
P7Malfunction or Protection: Evaporator high temperature protection
P8Malfunction or Protection: Typhoon protection

Outdoor Unit
Fault Codes原因
E2Malfunction or Protection: Communication malfunction between indoor/outdoor units
E4Malfunction or Protection: T3 and T4 temperature sensor malfunction
E5Malfunction or Protection: Power voltage protection
E6Malfunction or Protection: Fan Protection
E7Malfunction or Protection: Compressor discharge temperature sensor malfunction
E9Malfunction or Protection: EEPROM malfunction
EAMalfunction or Protection: A fan in the Aregion run for more than 5 minutes in Heat mode
EbMalfunction or Protection: 2 times of E6 protection in 10 minutes
H0Malfunction or Protection: Communication malfunction between IR341/main board
P1Malfunction or Protection: Hi-pressure protection
P2Malfunction or Protection: Low-pressure protection
P3Malfunction or Protection: Input current protection
P4Malfunction or Protection: Compressor discharge protection temperature
P5Malfunction or Protection: Condenser high temperature protection
P6Malfunction or Protection: Inverter module protection
P8Malfunction or Protection: Typhoon protection
PEMalfunction or Protection: Indoor evaporator hi-temp protection