{"id":1765,"date":"2025-07-19T02:29:13","date_gmt":"2025-07-19T06:29:13","guid":{"rendered":"http:\/\/www.jckhvac.com\/?p=1765"},"modified":"2025-07-20T17:46:24","modified_gmt":"2025-07-20T21:46:24","slug":"mitsubishi-4220-4225-4226-error-code","status":"publish","type":"post","link":"http:\/\/www.jckhvac.com\/zh\/mitsubishi-4220-4225-4226-error-code\/","title":{"rendered":"Mitsubishi 4220, 4225, 4226 Error Code"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" width=\"213\" height=\"54\" data-src=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/logo-1.png\" alt=\"\" class=\"wp-image-97 lazyload\" style=\"--smush-placeholder-width: 213px; --smush-placeholder-aspect-ratio: 213\/54;width:247px;height:auto\" data-srcset=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/logo-1.png 213w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/logo-1-18x5.png 18w\" data-sizes=\"(max-width: 213px) 100vw, 213px\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-mitsubishi-air-conditioner-error-codes\"><a href=\"http:\/\/www.jckhvac.com\/mitsubishi-air-conditioner-error-codes\/\">Mitsubishi Air Conditioner Error Codes<\/a><\/h2>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-mitsubishi-4220-4225-4226-error-code\">Mitsubishi 4220, 4225, 4226 Error Code<\/h2>\n\n\n\n<p><strong>1<\/strong>. Error code definition<br>Abnormal bus voltage drop (Detail code 108)<br><strong>2<\/strong>. Error definition and error detection method<br>If Vdc 289V or less is detected during Inverter operation. (S\/W detection)<br><strong>3<\/strong>. Cause, check method and remedy<\/p>\n\n\n\n<p><br>(1) Power supply environment<br>Check the power-supply wiring for an open phase. Refer to item (6) in section [6-1 Read before Test Run].<br>Find out if there was a (momentary) power failure.<br>Check whether the power voltage (Between L1 and L2, L2 and L3, and L1 and L3) is 342V or less across all phases.<br>(2) Voltage drop detected<br>4220 INV35Y and INV37YC<br>Check the voltage at relay connector RYPN while the inverter is stopped.<br>If the voltage is 420 V or above, check the following items.<br>1) Check the LED monitor to see if the bus voltage is above 289 V, and replace the inverter board if it is 289 V or below.<br>2) Check the coil (L) connections and for broken wiring.<br>3) Check the wiring connections between noise filter board and INV board.<br>4) If the problem persists after reboot, replace the INV board.If the voltage is below 420 V, check the following items.<br>1) Check the coil (L) connections and for broken wiring.<br>2) Check the wiring connections between noise filter board and INV board and between INV board and R1 through R5.<br>3) Check the in-rush current resistor. Refer to the following page(s). [8-10-14 Simple Check on Inverter Circuit Compo\u0002nents]<br>4) If the problem persists after reboot, replace the INV board. INV36Y and INV42Y<br>Check the voltage at relay connector RYPN while the inverter is stopped. If the voltage is 420 V or above, check the following items.<br>1) Check the LED monitor to see if the bus voltage is above 289 V, and replace the inverter board if it is 289 V or below.<br>2) Check the coil (L) connections and for broken wiring.<br>3) Check the wiring connections between noise filter board and INV board and between INV board and capacitor board.<br>4) If the problem persists after reboot, replace the INV board.<br>If the voltage is below 420 V, check the following items.<br>1) Check the coil (L) connections and for broken wiring.<br>2) Check the wiring connections between noise filter board and INV board, between INV board and capacitor board, and<br>between INV board and R1 through R5.<br>3) Check the in-rush current resistor. Refer to the following page(s). [8-10-14 Simple Check on Inverter Circuit Compo\u0002nents]<br>4) If the problem persists after reboot, replace the INV board.<br>4225, 4226<br>Check the voltage at relay connector RYPN while the inverter is stopped. If the voltage is below 420 V, check the following items.<br>1) Check for proper connections of noise filter coil and DC reactor, and for broken wiring.<br>2) Check the wiring connections between INV board and FAN board.<br>3) Check item for 4220<br>Replace the FAN board if no problems are found.<br>Check the voltage at connector RYPN while the inverter is stopped. If the voltage is 420 V or above, check the following items.<br>1) Check the state of the wiring connections between the INV board and the Fan board.<br>2) Check contents 4220<br>Replace the Fan board if no problems are found.<br>(3) Control board failure<br>Check that 12VDC is applied to connector CN72 on the control board while the inverter is operating. If voltage is absent or<br>the wrong voltage is applied, check the fuse F01. Replace the control board if no problems are found with the fuse.<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-cover has-custom-content-position is-position-top-center\"><img decoding=\"async\" width=\"1000\" height=\"667\" class=\"wp-block-cover__image-background wp-image-128 lazyload\" alt=\"\" data-src=\"http:\/\/47.89.137.65\/wp-content\/uploads\/2025\/04\/shutterstock_749942077.jpg\" data-object-fit=\"cover\" data-srcset=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/shutterstock_749942077.jpg 1000w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/shutterstock_749942077-300x200.jpg 300w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/shutterstock_749942077-768x512.jpg 768w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/shutterstock_749942077-18x12.jpg 18w\" data-sizes=\"(max-width: 1000px) 100vw, 1000px\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" style=\"--smush-placeholder-width: 1000px; --smush-placeholder-aspect-ratio: 1000\/667;\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-60 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-cover\" style=\"min-height:213px;aspect-ratio:unset;\"><img decoding=\"async\" width=\"385\" height=\"371\" class=\"wp-block-cover__image-background wp-image-307 lazyload\" alt=\"\" data-src=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/wx-1.png\" data-object-fit=\"cover\" data-srcset=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/wx-1.png 385w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/wx-1-300x289.png 300w, http:\/\/www.jckhvac.com\/wp-content\/smush-webp\/2025\/05\/wx-1-12x12.png.webp 12w\" data-sizes=\"(max-width: 385px) 100vw, 385px\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" style=\"--smush-placeholder-width: 385px; --smush-placeholder-aspect-ratio: 385\/371;\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-large-font-size\"><img decoding=\"async\" width=\"110\" height=\"110\" class=\"wp-image-301 lazyload\" style=\"--smush-placeholder-width: 110px; --smush-placeholder-aspect-ratio: 110\/110;width: 110px;\" data-src=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/wx.png\" alt=\"\" data-srcset=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/wx.png 815w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/wx-300x300.png 300w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/wx-150x150.png 150w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/wx-768x771.png 768w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/wx-12x12.png 12w\" data-sizes=\"(max-width: 110px) 100vw, 110px\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" \/><\/p>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" id=\"h-wechat\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-green-cyan-color\">WeChat<\/mark><\/strong><\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-cover\" style=\"min-height:214px;aspect-ratio:unset;\"><img decoding=\"async\" width=\"234\" height=\"215\" class=\"wp-block-cover__image-background wp-image-188 lazyload\" alt=\"\" data-src=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/WeChatOnline.jpg\" data-object-fit=\"cover\" data-srcset=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/WeChatOnline.jpg 234w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/WeChatOnline-13x12.jpg 13w\" data-sizes=\"(max-width: 234px) 100vw, 234px\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" style=\"--smush-placeholder-width: 234px; --smush-placeholder-aspect-ratio: 234\/215;\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<p class=\"has-text-align-center has-large-font-size\"><img decoding=\"async\" width=\"110\" height=\"111\" class=\"wp-image-290 lazyload\" style=\"--smush-placeholder-width: 110px; --smush-placeholder-aspect-ratio: 110\/111;width: 110px;\" data-src=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/\u5fae\u4fe1\u56fe\u7247_20250424114720.jpg\" alt=\"\" data-srcset=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/\u5fae\u4fe1\u56fe\u7247_20250424114720.jpg 481w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/\u5fae\u4fe1\u56fe\u7247_20250424114720-298x300.jpg 298w, http:\/\/www.jckhvac.com\/wp-content\/smush-webp\/2025\/05\/\u5fae\u4fe1\u56fe\u7247_20250424114720-150x150.jpg.webp 150w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/\u5fae\u4fe1\u56fe\u7247_20250424114720-12x12.jpg 12w\" data-sizes=\"(max-width: 110px) 100vw, 110px\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" \/><\/p>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" id=\"h-whats\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-green-cyan-color\">Whats<\/mark><\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img decoding=\"async\" width=\"164\" height=\"163\" data-src=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/24-7_\u526f\u672c.png\" alt=\"\" class=\"wp-image-653 lazyload\" style=\"--smush-placeholder-width: 164px; --smush-placeholder-aspect-ratio: 164\/163;width:180px;height:auto\" data-srcset=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/24-7_\u526f\u672c.png 164w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/24-7_\u526f\u672c-150x150.png 150w, http:\/\/www.jckhvac.com\/wp-content\/smush-webp\/2025\/05\/24-7_\u526f\u672c-12x12.png.webp 12w\" data-sizes=\"(max-width: 164px) 100vw, 164px\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" id=\"h-tel-347-987-6766\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-white-color\">Tel\uff1a<\/mark><a href=\"https:\/\/wa.me\/3479876766?text=Hello\" target=\"_blank\" rel=\"noreferrer noopener nofollow\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-white-color\">347-987-6766<\/mark><\/a><\/strong><\/h2>\n\n\n\n<p class=\"has-text-align-center\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-white-color\"><strong>Email: jckhvac212@gmail.com<\/strong> <\/mark><\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<p class=\"has-text-align-left\"><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-white-color\">JK HVAC We install, repair and service all brands of air conditioners! Including air conditioner cleaning, dryer vent cleaning, furnace repair.<\/mark><\/strong><\/p>\n\n\n\n<p class=\"has-text-align-left\">\ud83d\udccd <strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-white-color\">Serving all of New York City: Manhattan, Brooklyn, Staten Island, Queens\u2026<\/mark><\/strong><\/p>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Mitsubishi 4220, 4225, 4226 Error Code 1. Error code definitionAbnormal bus voltage drop (Detail code 108)2. Error definition and error detection methodIf Vdc 289V or less is detected during Inverter operation. (S\/W detection)3. Cause, check method and remedy (1) Power supply environmentCheck the power-supply wiring for an open phase. Refer to item (6) in section [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[26],"tags":[29,28],"class_list":["post-1765","post","type-post","status-publish","format-standard","hentry","category-mitsubishi-error-code","tag-29","tag-mitsubishi-4220"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.9 (Yoast SEO v26.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Mitsubishi 4220, 4225, 4226 Error Code - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/www.jckhvac.com\/zh\/mitsubishi-4220-4225-4226-error-code\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Mitsubishi 4220, 4225, 4226 Error Code\" \/>\n<meta property=\"og:description\" content=\"Mitsubishi 4220, 4225, 4226 Error Code 1. Error code definitionAbnormal bus voltage drop (Detail code 108)2. Error definition and error detection methodIf Vdc 289V or less is detected during Inverter operation. (S\/W detection)3. Cause, check method and remedy (1) Power supply environmentCheck the power-supply wiring for an open phase. Refer to item (6) in section [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"http:\/\/www.jckhvac.com\/zh\/mitsubishi-4220-4225-4226-error-code\/\" \/>\n<meta property=\"og:site_name\" content=\"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8\" \/>\n<meta property=\"article:published_time\" content=\"2025-07-19T06:29:13+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-20T21:46:24+00:00\" \/>\n<meta name=\"author\" content=\"\u80af\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"\u80af\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/#article\",\"isPartOf\":{\"@id\":\"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/\"},\"author\":{\"name\":\"\u80af\",\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\"},\"headline\":\"Mitsubishi 4220, 4225, 4226 Error Code\",\"datePublished\":\"2025-07-19T06:29:13+00:00\",\"dateModified\":\"2025-07-20T21:46:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/\"},\"wordCount\":553,\"publisher\":{\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\"},\"keywords\":[\"4225\",\"Mitsubishi 4220\"],\"articleSection\":[\"Mitsubishi Error Code\"],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/\",\"url\":\"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/\",\"name\":\"Mitsubishi 4220, 4225, 4226 Error Code - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8\",\"isPartOf\":{\"@id\":\"http:\/\/www.jckhvac.com\/#website\"},\"datePublished\":\"2025-07-19T06:29:13+00:00\",\"dateModified\":\"2025-07-20T21:46:24+00:00\",\"breadcrumb\":{\"@id\":\"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"http:\/\/www.jckhvac.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Mitsubishi 4220, 4225, 4226 Error Code\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.jckhvac.com\/#website\",\"url\":\"http:\/\/www.jckhvac.com\/\",\"name\":\"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8\",\"description\":\"New York Heating &amp; Air Conditioning\",\"publisher\":{\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\/\/www.jckhvac.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\",\"name\":\"\u80af\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/\",\"url\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png\",\"contentUrl\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png\",\"width\":200,\"height\":200,\"caption\":\"\u80af\"},\"logo\":{\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/\"},\"sameAs\":[\"http:\/\/www.jckhvac.com\/\"],\"url\":\"http:\/\/www.jckhvac.com\/zh\/author\/ken\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Mitsubishi 4220, 4225, 4226 Error Code - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/www.jckhvac.com\/zh\/mitsubishi-4220-4225-4226-error-code\/","og_locale":"zh_CN","og_type":"article","og_title":"Mitsubishi 4220, 4225, 4226 Error Code","og_description":"Mitsubishi 4220, 4225, 4226 Error Code 1. Error code definitionAbnormal bus voltage drop (Detail code 108)2. Error definition and error detection methodIf Vdc 289V or less is detected during Inverter operation. (S\/W detection)3. Cause, check method and remedy (1) Power supply environmentCheck the power-supply wiring for an open phase. Refer to item (6) in section [&hellip;]","og_url":"http:\/\/www.jckhvac.com\/zh\/mitsubishi-4220-4225-4226-error-code\/","og_site_name":"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","article_published_time":"2025-07-19T06:29:13+00:00","article_modified_time":"2025-07-20T21:46:24+00:00","author":"\u80af","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"\u80af","\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"4 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/#article","isPartOf":{"@id":"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/"},"author":{"name":"\u80af","@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260"},"headline":"Mitsubishi 4220, 4225, 4226 Error Code","datePublished":"2025-07-19T06:29:13+00:00","dateModified":"2025-07-20T21:46:24+00:00","mainEntityOfPage":{"@id":"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/"},"wordCount":553,"publisher":{"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260"},"keywords":["4225","Mitsubishi 4220"],"articleSection":["Mitsubishi Error Code"],"inLanguage":"zh-Hans"},{"@type":"WebPage","@id":"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/","url":"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/","name":"Mitsubishi 4220, 4225, 4226 Error Code - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","isPartOf":{"@id":"http:\/\/www.jckhvac.com\/#website"},"datePublished":"2025-07-19T06:29:13+00:00","dateModified":"2025-07-20T21:46:24+00:00","breadcrumb":{"@id":"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/"]}]},{"@type":"BreadcrumbList","@id":"http:\/\/www.jckhvac.com\/mitsubishi-4220-4225-4226-error-code\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"http:\/\/www.jckhvac.com\/"},{"@type":"ListItem","position":2,"name":"Mitsubishi 4220, 4225, 4226 Error Code"}]},{"@type":"WebSite","@id":"http:\/\/www.jckhvac.com\/#website","url":"http:\/\/www.jckhvac.com\/","name":"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","description":"New York Heating &amp; Air Conditioning","publisher":{"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/www.jckhvac.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":["Person","Organization"],"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260","name":"\u80af","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/","url":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png","contentUrl":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png","width":200,"height":200,"caption":"\u80af"},"logo":{"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/"},"sameAs":["http:\/\/www.jckhvac.com\/"],"url":"http:\/\/www.jckhvac.com\/zh\/author\/ken\/"}]}},"_links":{"self":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts\/1765","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/comments?post=1765"}],"version-history":[{"count":2,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts\/1765\/revisions"}],"predecessor-version":[{"id":1767,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts\/1765\/revisions\/1767"}],"wp:attachment":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/media?parent=1765"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/categories?post=1765"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/tags?post=1765"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}