{"id":1858,"date":"2026-02-23T23:36:37","date_gmt":"2026-02-24T04:36:37","guid":{"rendered":"http:\/\/www.jckhvac.com\/?p=1858"},"modified":"2026-02-23T23:38:08","modified_gmt":"2026-02-24T04:38:08","slug":"daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor","status":"publish","type":"post","link":"http:\/\/www.jckhvac.com\/zh\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/","title":{"rendered":"Daikin &#8211; Reading thermostat temperature sensor instead of return air temperature sensor"},"content":{"rendered":"<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" width=\"245\" height=\"234\" data-src=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg\" alt=\"\" class=\"wp-image-1859 lazyload\" style=\"--smush-placeholder-width: 245px; --smush-placeholder-aspect-ratio: 245\/234;aspect-ratio:1.0470723306544203;width:304px;height:auto\" data-srcset=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg 245w, http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713-13x12.jpg 13w\" data-sizes=\"(max-width: 245px) 100vw, 245px\" src=\"data:image\/gif;base64,R0lGODlhAQABAAAAACH5BAEKAAEALAAAAAABAAEAAAICTAEAOw==\" \/><\/figure>\n\n\n\n<p>This function is controlled from the unit&#8217;s local wired controller (like BRC1E72).<\/p>\n\n\n\n<p>Here are the settings to be made in order to activate:<\/p>\n\n\n\n<p>CoolMaster will read ambient temperature measured by thermostat &#8211; local wired controller (like BRC1E72) if following field settings had being done on thermostat:<\/p>\n\n\n\n<p>Setting\u00a0<strong>10-2<\/strong>\u00a0= 03 &#8211; Only the thermostat thermistor will be utilized by indoor unit.<br>Setting\u00a0<strong>10-5<\/strong>\u00a0= 02 &#8211; Room temperature value reported to by Indoor is taken from thermostat.<\/p>","protected":false},"excerpt":{"rendered":"<p>This function is controlled from the unit&#8217;s local wired controller (like BRC1E72). Here are the settings to be made in order to activate: CoolMaster will read ambient temperature measured by thermostat &#8211; local wired controller (like BRC1E72) if following field settings had being done on thermostat: Setting\u00a010-2\u00a0= 03 &#8211; Only the thermostat thermistor will be [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4,8,1],"tags":[],"class_list":["post-1858","post","type-post","status-publish","format-standard","hentry","category-about-air-conditioning","category-repair","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.9 (Yoast SEO v26.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Daikin - Reading thermostat temperature sensor instead of return air temperature sensor - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/www.jckhvac.com\/zh\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Daikin - Reading thermostat temperature sensor instead of return air temperature sensor\" \/>\n<meta property=\"og:description\" content=\"This function is controlled from the unit&#8217;s local wired controller (like BRC1E72). Here are the settings to be made in order to activate: CoolMaster will read ambient temperature measured by thermostat &#8211; local wired controller (like BRC1E72) if following field settings had being done on thermostat: Setting\u00a010-2\u00a0= 03 &#8211; Only the thermostat thermistor will be [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"http:\/\/www.jckhvac.com\/zh\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/\" \/>\n<meta property=\"og:site_name\" content=\"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-24T04:36:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-24T04:38:08+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"245\" \/>\n\t<meta property=\"og:image:height\" content=\"234\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"\u80af\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"\u80af\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#article\",\"isPartOf\":{\"@id\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/\"},\"author\":{\"name\":\"\u80af\",\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\"},\"headline\":\"Daikin &#8211; Reading thermostat temperature sensor instead of return air temperature sensor\",\"datePublished\":\"2026-02-24T04:36:37+00:00\",\"dateModified\":\"2026-02-24T04:38:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/\"},\"wordCount\":87,\"commentCount\":0,\"publisher\":{\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\"},\"image\":{\"@id\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg\",\"articleSection\":[\"About air conditioning\",\"Repair\"],\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/\",\"url\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/\",\"name\":\"Daikin - Reading thermostat temperature sensor instead of return air temperature sensor - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8\",\"isPartOf\":{\"@id\":\"http:\/\/www.jckhvac.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#primaryimage\"},\"image\":{\"@id\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg\",\"datePublished\":\"2026-02-24T04:36:37+00:00\",\"dateModified\":\"2026-02-24T04:38:08+00:00\",\"breadcrumb\":{\"@id\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#primaryimage\",\"url\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg\",\"contentUrl\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"http:\/\/www.jckhvac.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Daikin &#8211; Reading thermostat temperature sensor instead of return air temperature sensor\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.jckhvac.com\/#website\",\"url\":\"http:\/\/www.jckhvac.com\/\",\"name\":\"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8\",\"description\":\"New York Heating &amp; Air Conditioning\",\"publisher\":{\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\/\/www.jckhvac.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\",\"name\":\"\u80af\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/\",\"url\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png\",\"contentUrl\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png\",\"width\":200,\"height\":200,\"caption\":\"\u80af\"},\"logo\":{\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/\"},\"sameAs\":[\"http:\/\/www.jckhvac.com\/\"],\"url\":\"http:\/\/www.jckhvac.com\/zh\/author\/ken\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Daikin - Reading thermostat temperature sensor instead of return air temperature sensor - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/www.jckhvac.com\/zh\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/","og_locale":"zh_CN","og_type":"article","og_title":"Daikin - Reading thermostat temperature sensor instead of return air temperature sensor","og_description":"This function is controlled from the unit&#8217;s local wired controller (like BRC1E72). Here are the settings to be made in order to activate: CoolMaster will read ambient temperature measured by thermostat &#8211; local wired controller (like BRC1E72) if following field settings had being done on thermostat: Setting\u00a010-2\u00a0= 03 &#8211; Only the thermostat thermistor will be [&hellip;]","og_url":"http:\/\/www.jckhvac.com\/zh\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/","og_site_name":"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","article_published_time":"2026-02-24T04:36:37+00:00","article_modified_time":"2026-02-24T04:38:08+00:00","og_image":[{"width":245,"height":234,"url":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg","type":"image\/jpeg"}],"author":"\u80af","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"\u80af","\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"1 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#article","isPartOf":{"@id":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/"},"author":{"name":"\u80af","@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260"},"headline":"Daikin &#8211; Reading thermostat temperature sensor instead of return air temperature sensor","datePublished":"2026-02-24T04:36:37+00:00","dateModified":"2026-02-24T04:38:08+00:00","mainEntityOfPage":{"@id":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/"},"wordCount":87,"commentCount":0,"publisher":{"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260"},"image":{"@id":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#primaryimage"},"thumbnailUrl":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg","articleSection":["About air conditioning","Repair"],"inLanguage":"zh-Hans","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#respond"]}]},{"@type":"WebPage","@id":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/","url":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/","name":"Daikin - Reading thermostat temperature sensor instead of return air temperature sensor - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","isPartOf":{"@id":"http:\/\/www.jckhvac.com\/#website"},"primaryImageOfPage":{"@id":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#primaryimage"},"image":{"@id":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#primaryimage"},"thumbnailUrl":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg","datePublished":"2026-02-24T04:36:37+00:00","dateModified":"2026-02-24T04:38:08+00:00","breadcrumb":{"@id":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#primaryimage","url":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg","contentUrl":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2026\/02\/BRC1E72__53713.jpg"},{"@type":"BreadcrumbList","@id":"http:\/\/www.jckhvac.com\/daikin-reading-thermostat-temperature-sensor-instead-of-return-air-temperature-sensor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"http:\/\/www.jckhvac.com\/"},{"@type":"ListItem","position":2,"name":"Daikin &#8211; Reading thermostat temperature sensor instead of return air temperature sensor"}]},{"@type":"WebSite","@id":"http:\/\/www.jckhvac.com\/#website","url":"http:\/\/www.jckhvac.com\/","name":"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","description":"New York Heating &amp; Air Conditioning","publisher":{"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/www.jckhvac.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":["Person","Organization"],"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260","name":"\u80af","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/","url":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png","contentUrl":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png","width":200,"height":200,"caption":"\u80af"},"logo":{"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/"},"sameAs":["http:\/\/www.jckhvac.com\/"],"url":"http:\/\/www.jckhvac.com\/zh\/author\/ken\/"}]}},"_links":{"self":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts\/1858","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/comments?post=1858"}],"version-history":[{"count":4,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts\/1858\/revisions"}],"predecessor-version":[{"id":1863,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts\/1858\/revisions\/1863"}],"wp:attachment":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/media?parent=1858"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/categories?post=1858"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/tags?post=1858"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}