{"id":236,"date":"2025-05-01T02:30:26","date_gmt":"2025-05-01T06:30:26","guid":{"rendered":"http:\/\/47.89.137.65\/?p=236"},"modified":"2025-05-27T13:36:08","modified_gmt":"2025-05-27T17:36:08","slug":"amana-furnace-error-codes","status":"publish","type":"post","link":"http:\/\/www.jckhvac.com\/zh\/amana-furnace-error-codes\/","title":{"rendered":"Amana \u7089\u9519\u8bef\u4ee3\u7801"},"content":{"rendered":"<p>Amana HVAC \u7cfb\u7edf\u4e5f\u9ad8\u5ea6\u53ef\u9760\u4e14\u9ad8\u6548\u3002\u4e0e Trane \u6696\u6c14\u7089\u7c7b\u4f3c\uff0cAmana \u6696\u6c14\u7089\u4f7f\u7528\u95ea\u70c1\u7684\u7ea2\u706f\u6765\u8868\u793a\u8bbe\u5907\u51fa\u73b0\u95ee\u9898\u3002&nbsp;<\/p>\n\n\n\n<p>\u623f\u4e3b\u53ef\u80fd\u4f1a\u9047\u5230\u8fd9\u4e9b\u5e38\u89c1\u7684 Amana \u7089\u9519\u8bef\u4ee3\u7801\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Amana Furnace Error Code<\/strong><\/td><td><strong>\u539f\u56e0<\/strong><\/td><td><strong>\u6f5c\u5728\u95ee\u9898<\/strong><\/td><\/tr><tr><td>Constant red light<\/td><td>No signal from thermostat<\/td><td>No power, issue with connections<\/td><\/tr><tr><td>Constant flashing<\/td><td>\u6781\u6027\u53cd\u8f6c<\/td><td>Issue with wiring or line voltage polarity<\/td><\/tr><tr><td>1 flash<\/td><td>Flame failure \/ Lockout due to excessive ignition retries<\/td><td>Gas supply interruption, flame rod not sensing flame, wiring issue, etc.<\/td><\/tr><tr><td>2 flashes<\/td><td>Draft inducer not operating or pressure switch failure (closed pressure switch circuit)<\/td><td>Draft inducer not working, short in the pressure switch, blockage in vent, condensate drain plugged, etc.<\/td><\/tr><tr><td>3 flashes<\/td><td>Open pressure switch<\/td><td>Pressure switch needs to be replaced, pressure switch hose improperly connected or blocked, loose wiring, etc.<\/td><\/tr><tr><td>4 flashes<\/td><td>Pressure error \/ High limit error<\/td><td>Clogged air filter, drain tubes obstructed by debris or moisture, faulty wiring, etc.<\/td><\/tr><tr><td>5 flashes<\/td><td>Flame sensed without call for heat<\/td><td>Valve closing too slowly, etc.<\/td><\/tr><tr><td>7 flashes<\/td><td>Faulty flame sensor<\/td><td>Flame sensor dirty or too far from flame, etc.<\/td><\/tr><\/tbody><\/table><\/figure>","protected":false},"excerpt":{"rendered":"<p>Amana HVAC&nbsp;systems are also highly-dependable and efficient. Similar to Trane furnaces, Amana furnaces use a blinking red light to signify an issue with the unit.&nbsp; Homeowners may encounter these common Amana furnace error codes. Amana Furnace Error Code Meaning Potential Issue Constant red light No signal from thermostat No power, issue with connections Constant flashing [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":725,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[7],"tags":[],"class_list":["post-236","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-error-codes"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.9 (Yoast SEO v26.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Amana Furnace Error Codes - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"http:\/\/www.jckhvac.com\/zh\/amana-furnace-error-codes\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Amana Furnace Error Codes\" \/>\n<meta property=\"og:description\" content=\"Amana HVAC&nbsp;systems are also highly-dependable and efficient. Similar to Trane furnaces, Amana furnaces use a blinking red light to signify an issue with the unit.&nbsp; Homeowners may encounter these common Amana furnace error codes. Amana Furnace Error Code Meaning Potential Issue Constant red light No signal from thermostat No power, issue with connections Constant flashing [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"http:\/\/www.jckhvac.com\/zh\/amana-furnace-error-codes\/\" \/>\n<meta property=\"og:site_name\" content=\"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8\" \/>\n<meta property=\"article:published_time\" content=\"2025-05-01T06:30:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-27T17:36:08+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/images.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"237\" \/>\n\t<meta property=\"og:image:height\" content=\"212\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"\u80af\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"\u80af\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#article\",\"isPartOf\":{\"@id\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/\"},\"author\":{\"name\":\"\u80af\",\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\"},\"headline\":\"Amana Furnace Error Codes\",\"datePublished\":\"2025-05-01T06:30:26+00:00\",\"dateModified\":\"2025-05-27T17:36:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/\"},\"wordCount\":184,\"publisher\":{\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\"},\"image\":{\"@id\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/images.jpeg\",\"articleSection\":[\"Error Codes\"],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"WebPage\",\"@id\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/\",\"url\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/\",\"name\":\"Amana Furnace Error Codes - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8\",\"isPartOf\":{\"@id\":\"http:\/\/www.jckhvac.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#primaryimage\"},\"image\":{\"@id\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/images.jpeg\",\"datePublished\":\"2025-05-01T06:30:26+00:00\",\"dateModified\":\"2025-05-27T17:36:08+00:00\",\"breadcrumb\":{\"@id\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#primaryimage\",\"url\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/images.jpeg\",\"contentUrl\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/images.jpeg\",\"width\":237,\"height\":212},{\"@type\":\"BreadcrumbList\",\"@id\":\"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"http:\/\/www.jckhvac.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Amana Furnace Error Codes\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\/\/www.jckhvac.com\/#website\",\"url\":\"http:\/\/www.jckhvac.com\/\",\"name\":\"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8\",\"description\":\"New York Heating &amp; Air Conditioning\",\"publisher\":{\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\/\/www.jckhvac.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":[\"Person\",\"Organization\"],\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260\",\"name\":\"\u80af\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/\",\"url\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png\",\"contentUrl\":\"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png\",\"width\":200,\"height\":200,\"caption\":\"\u80af\"},\"logo\":{\"@id\":\"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/\"},\"sameAs\":[\"http:\/\/www.jckhvac.com\/\"],\"url\":\"http:\/\/www.jckhvac.com\/zh\/author\/ken\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Amana Furnace Error Codes - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"http:\/\/www.jckhvac.com\/zh\/amana-furnace-error-codes\/","og_locale":"zh_CN","og_type":"article","og_title":"Amana Furnace Error Codes","og_description":"Amana HVAC&nbsp;systems are also highly-dependable and efficient. Similar to Trane furnaces, Amana furnaces use a blinking red light to signify an issue with the unit.&nbsp; Homeowners may encounter these common Amana furnace error codes. Amana Furnace Error Code Meaning Potential Issue Constant red light No signal from thermostat No power, issue with connections Constant flashing [&hellip;]","og_url":"http:\/\/www.jckhvac.com\/zh\/amana-furnace-error-codes\/","og_site_name":"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","article_published_time":"2025-05-01T06:30:26+00:00","article_modified_time":"2025-05-27T17:36:08+00:00","og_image":[{"width":237,"height":212,"url":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/images.jpeg","type":"image\/jpeg"}],"author":"\u80af","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"\u80af","\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"2 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#article","isPartOf":{"@id":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/"},"author":{"name":"\u80af","@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260"},"headline":"Amana Furnace Error Codes","datePublished":"2025-05-01T06:30:26+00:00","dateModified":"2025-05-27T17:36:08+00:00","mainEntityOfPage":{"@id":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/"},"wordCount":184,"publisher":{"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260"},"image":{"@id":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#primaryimage"},"thumbnailUrl":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/images.jpeg","articleSection":["Error Codes"],"inLanguage":"zh-Hans"},{"@type":"WebPage","@id":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/","url":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/","name":"Amana Furnace Error Codes - \u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","isPartOf":{"@id":"http:\/\/www.jckhvac.com\/#website"},"primaryImageOfPage":{"@id":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#primaryimage"},"image":{"@id":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#primaryimage"},"thumbnailUrl":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/images.jpeg","datePublished":"2025-05-01T06:30:26+00:00","dateModified":"2025-05-27T17:36:08+00:00","breadcrumb":{"@id":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#primaryimage","url":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/images.jpeg","contentUrl":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/05\/images.jpeg","width":237,"height":212},{"@type":"BreadcrumbList","@id":"http:\/\/www.jckhvac.com\/amana-furnace-error-codes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"http:\/\/www.jckhvac.com\/"},{"@type":"ListItem","position":2,"name":"Amana Furnace Error Codes"}]},{"@type":"WebSite","@id":"http:\/\/www.jckhvac.com\/#website","url":"http:\/\/www.jckhvac.com\/","name":"\u7ebd\u7ea6\u5408\u6210\u51b7\u6696\u5de5\u7a0b\u516c\u53f8","description":"New York Heating &amp; Air Conditioning","publisher":{"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/www.jckhvac.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":["Person","Organization"],"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/a40238e88a2bd3649b4736dcd71c6260","name":"\u80af","image":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/","url":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png","contentUrl":"http:\/\/www.jckhvac.com\/wp-content\/uploads\/2025\/04\/unnamed.png","width":200,"height":200,"caption":"\u80af"},"logo":{"@id":"http:\/\/www.jckhvac.com\/#\/schema\/person\/image\/"},"sameAs":["http:\/\/www.jckhvac.com\/"],"url":"http:\/\/www.jckhvac.com\/zh\/author\/ken\/"}]}},"_links":{"self":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts\/236","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/comments?post=236"}],"version-history":[{"count":2,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts\/236\/revisions"}],"predecessor-version":[{"id":723,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/posts\/236\/revisions\/723"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/media\/725"}],"wp:attachment":[{"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/media?parent=236"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/categories?post=236"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.jckhvac.com\/zh\/wp-json\/wp\/v2\/tags?post=236"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}